I2C 대 SPI 압력 센서의 차이점

In our daily applications, barometric sensors often use two main digital interfaces: I²C (also called IIC) and SPI. Knowing their differences, performance, and use cases helps engineers and hobbyists pick the right one and optimize system designs. Walk you through:

목록

1. Defining I²C vs. SPI Pressure Sensors

I²C (Inter‑Integrated Circuit) and SPI (Serial Peripheral Interface) are common digital bus protocols used between microcontrollers and MEMS barometric sensors.

1.1 Basics of I²C

  • Two wires: Clock (SCL) and Data (SDA).

  • Multi-master/multi-slave on one bus, addresses identify devices.

  • Half‑duplex: Send or receive at one time.

1.2 Basics of SPI

  • Four wires: SCLK, MOSI, MISO, and CS.

  • Single-master/multiple-slave, use CS to select slaves.

  • Full‑duplex: Simultaneous read/write.

1.3 Barometer Use Cases

  • I²C sensors: Fewer lines, lower cost, better for tight pin budgets and many devices.

  • SPI sensors: Higher speed, stronger noise immunity, ideal for time‑critical data.

I2C 및 SPI 디지털 센서 핀 사진

비고: SOP 및 DIP 패키지 제품의 연결 정의는 동일합니다.

2. Is IIC the Same as I²C?

IIC is simply an old spelling of I²C—same protocol, same features.

2.1 Naming History

  • I²C: Coined by Philips (now NXP) as “Inter-Integrated Circuit.”

  • IIC: Simplified shorthand in older datasheets.

2.2 Identical Specifications

Whether IIC or I²C, voltage levels, timing, and addressing match exactly—drivers are interchangeable.

2.3 Practical Tip

When you see IIC in docs, treat it as I²C—no extra learning needed.

3. Speed Comparison: I²C vs. SPI

Speed often drives your interface choice.

3.1 I²C Speeds

  • Standard: up to 100 kHz

  • Fast: up to 400 kHz

  • Fast‑Plus: up to 1 MHz (device‑dependent)

3.2 SPI Speeds

  • Commonly several MHz up to tens of MHz; some designs reach 100 MHz

  • Depends on line length, capacitance, and MCU capability

3.3 Throughput in Practice

SPI’s full‑duplex mode lets you send and receive at once. I²C’s half‑duplex plus address overhead slows it down. At 1 MHz, I²C sends 2 bytes in ~20 μs; at 10 MHz, SPI does it in ~1.6 μs.

4. Using SPI and I²C Together

Sometimes you need both buses in one system.

4.1 Hardware Sharing

  • Use separate pins or a multiplexer (MUX) to host both SPI and I²C on one MCU.

  • Watch level‑shifting and MUX timing requirements.

4.2 Driver Support

  • Platforms like STM32 or Arduino natively run both SPI and I²C drivers simultaneously.

  • Manage interrupts and DMA channels to avoid conflicts.

4.3 Real‑World Example

In our sensor application solution for a UAV barometer design, I²C is used for low-speed environmental monitoring and SPI for high-frequency data acquisition, both working in tandem for high resource utilization and no interference.

WF100DP 1kpa DIP6 Pressure Sensor

5. Signal Types & Levels: Analog or Digital? Active High or Low?

Both I²C and SPI are digital, but you still need to know signal behavior.

5.1 SPI Digital Signals

  • MOSI/MISO/SCLK are digital pulses.

  • CS is digital (usually active‑low).

5.2 I²C Digital Signals

  • SDA/SCL are open‑drain outputs, need pull‑ups.

  • Idle bus: both lines high; pull low for start, clock, or data‑0.

5.3 Logic Levels

For WF100DP digital sensor series modules:

  • SPI CS: typically “low‑active.”

  • I²C: “high” = idle/stop, “low” = start or data‑0 (or I2C, leave it alone).

6. Choice Guide: SPI or I²C?

When picking a barometric sensor interface, balance power, speed, pin count, and system layout.

6.1 When to Pick Which

  • 핀 - 핀 & 많은 장치 → I²C

  • 높은 대역폭 & 실시간 요구 → SPI

6.2 Hands‑On Advice

Start prototypes with I²C for quick tests. If you hit performance walls or stricter timing, switch to SPI. Always bench‑test error rates, power draw, and coding effort before locking in your choice.

결론

Through this article, we have made a comprehensive analysis of the definition, performance, parallel use, signal characteristics and selection points of I²C (IIC) and SPI in air pressure sensor applications. In short: I²C is simple, flexible and suitable for multiple expansion; SPI is high-speed, stable and suitable for real-time acquisition. We hope you will find the most suitable interface solution in your next barometer design, so that the device can save cost and have high precision resolution and sampling rate.

위의 소개는 압력 센서 기술 적용의 표면적인 부분에 불과합니다. 우리는 다양한 제품에 사용되는 다양한 유형의 센서 요소, 작동 방식, 장점과 단점을 계속해서 탐구할 것입니다. 여기에서 논의된 내용에 대해 더 자세히 알아보려면 이 가이드 뒷부분의 관련 콘텐츠를 확인하세요. 시간이 촉박한 경우 여기를 클릭하여 이 가이드의 세부정보를 다운로드할 수도 있습니다. 공기 압력 센서 제품 PDF 데이터.

다른 센서 기술에 대한 자세한 내용은 다음을 참조하십시오. 센서 페이지를 방문하십시오.

코멘트를 남겨주세요

귀하의 이메일 주소는 공개되지 않습니다. 필수 입력란이 표시되어 있습니다 *

맨 위로 스크롤

문의하기