1. Introduction to WF282A Sensor
Choosing the right pressure sensor is key for a DC motor–driven fan airflow project. The WF282A from WF sensors is a digital barometric sensor based on piezoresistive MEMS technology. It uses a silicon diaphragm whose resistance changes under pressure, combined with an on-chip 24‑bit ADC and calibration coefficients, to output precise pressure and temperature readings
1.1 Sensing Principle and Package
Inside WF282A , the piezoresistive diaphragm deforms under external pressure, creating a Wheatstone bridge output. This signal is amplified, filtered, and converted via a high‑resolution ADC. Compared to its predecessor WF282, WF282A is 63 % smaller, housed in an 8‑pin LGA metal package (2.0 × 2.5 × 0.98 mm³), offering excellent EMC robustness and long‑term stability

1.2 Key Specifications
Range: 300 hPa to 1100 hPa, covering altitudes from –500 m to +9000 m.
Typical Relative Accuracy: ±0.12 hPa (≈±1 m altitude).
Resolution: 0.01 hPa (≈1 Pa); typical RMS noise is 1.3 Pa, sufficient to resolve small static‑pressure changes from a fan.
Supply & Power: 1.71 – 3.6 V; 2.7 μA at 1 Hz refresh, 0.1 μA in sleep mode, ideal for battery‑powered systems.
Interface: I²C up to 3.4 MHz or SPI up to 10 MHz, for flexible microcontroller integration
1.3 Advantages and Considerations
Akurasi Tinggi, Low Drift: Bosch’s proven MEMS process yields excellent linearity and stability, with a temperature coefficient offset of only 1.5 Pa/K (≈12.6 cm/K).
Tiny Footprint, Ultra‑Low Power: Perfect for space‑ and power‑constrained applications, yet careful static‑port placement is needed to avoid dynamic‑pressure errors at high airflow speeds.
Configurable Filtering & Modes: On‑chip IIR filters and multiple power/measurement modes support sampling rates from 0.016 Hz to 157 Hz, adaptable to diverse requirements.
With its high resolution, low noise, minimal power draw, and flexible interface options, the WF282A is an ideal choice for measuring static pressure in fan‑driven airflow projects. Combined with a well‑designed static port, it can capture pressure changes on the order of a few pascals, laying a robust foundation for airflow estimation and performance analysis.
2. Project Background and Requirements
2.1 Project Objectives
The goal of this project is to estimate airflow intensity generated by a DC motor–driven fan at various speeds by measuring static pressure variations inside the fan duct, providing quantitative data for performance optimization and energy efficiency analysis. This method leverages the WF282A sensor’s high-resolution static-pressure measurement capability to convert pressure differentials into metrics proportional to airflow velocity and volumetric flow, helping engineers and DIY enthusiasts assess fan performance with intuitive numerical feedback. Compared to traditional anemometers or hot-wire sensors, a static-pressure-based approach offers easier installation, lower cost, and no direct exposure of the sensor diaphragm to high-velocity air streams, making it ideal for small duct or home fan monitoring applications.
2.2 Measurement Challenges
Static pressure differences produced by fans are typically below 200 Pa, requiring a sensor capable of resolving changes at the 1 Pa level or better to reliably detect the signal. Additionally, turbulence and pulsing in the airflow introduce noise, so without proper mechanical layout and data filtering strategies, pressure readings will fluctuate significantly, making it difficult to capture stable flow conditions. This static-pressure sampling technique is inspired by the pitot–static system commonly used in aviation to accurately measure airflow static pressure. Exposing the sensor directly to the airflow results in measurement of total pressure (static + dynamic), so a static port must be designed and placed away from direct flow impact—usually on the duct sidewall—and connected to the sensor via tubing to sample pure static pressure. Furthermore, ambient temperature and barometric drift can shift readings over time, necessitating baseline calibration and temperature compensation in software to maintain measurement accuracy.
2.3 WF282A Suitability Analysis
The WF282A sensor offers a measurement range of 300 – 1100 hPa, a typical relative accuracy of ±0.12 hPa, and resolution down to 0.01 hPa (≈1 Pa), with random noise around ±4 Pa—sufficient to capture the few-pascal-level static pressure changes produced by a fan. Its ultra‑low power consumption (≈2.7 μA at 1 Hz update rate) and miniature package (2.0 × 2.5 × 0.95 mm³) make it easy to embed in compact duct systems for continuous monitoring. The sensor includes on‑chip IIR filters and multiple oversampling modes configurable via registers, allowing a balance between sampling rate and noise reduction to improve signal stability without sacrificing resolution.
2.4 Design Approach
To achieve reliable static-pressure sampling, drill a series of 15 mm‑deep, 1 mm‑diameter static ports on the duct sidewall, then connect them to the WF282A pressure port via short tubing to isolate the sensor from direct airflow impact. The port location should avoid direct blade impingement—typically positioned mid‑blade or evenly along the duct—to capture representative static pressure data. Electrically, the WF282A communicates over I²C (up to 3.4 MHz) and connects to an Arduino or other microcontroller via four wires: VCC, GND, SDA, and SCL. A 4.7 kΩ pull‑up resistor is recommended on the bus lines to ensure stable readings and prevent drift. In software, enable appropriate oversampling and filtering (MISALNYA., 16× oversampling, IIR filter coefficient 4), and use a 500 ms sampling interval. Apply a moving average or exponential smoothing window (N=10) to reduce random noise, then convert absolute barometric pressure to relative static pressure change as required by the application.
3. Sensor Placement & Installation
3.1 Static‑Port Design
To measure pure static pressure, drill a dedicated static port on the duct sidewall. A typical port is a 1 mm diameter, 15 mm deep bore with a smooth internal finish to minimize local turbulence and vortices that can distort readings. Position the port away from direct blade impingement—ideally along the mid‑span of the duct wall—to sample undisturbed static pressure. Connect the port to the WF282A pressure inlet via a ≤ 30 mm length of silicone or PTFE tubing. This short, compliant tube provides a good balance between fast dynamic response and damping of transient spikes, ensuring you capture genuine pressure changes without excessive noise. This approach mirrors the pitot–static system used in aviation instrumentation, isolating static pressure measurements from dynamic pressure effects.
3.2 Mounting Location
Mount the sensor assembly on an external bracket or plate outside the main airflow path, protecting it from mechanical vibration and particulate impact while allowing easy access. The ideal location is mid‑duct outer wall, which offers a representative static pressure sample and stays clear of local blade‑tip vortices. For longer ducts or to improve noise rejection, multiple static ports can be spaced at inlet, midpoint, and outlet positions; then the WF282A can poll each in sequence and average results for a more stable reading. Ensure the module is oriented level so gravitational forces do not bias the MEMS diaphragm.
3.3 Sealing & Protection
Seal all tubing and sensor interfaces with neutral‑cure silicone and tighten hose clamps to achieve leak rates < 0.1 Pa/s, preventing false pressure drops due to leaks. Cover the port and sensor vents with fine‑mesh stainless steel or nylon screens (mesh < 0.5 mm) to block dust and water droplets. In humid environments, add a hydrophobic membrane inline to shed any condensation without restricting airflow. For long‑term deployments, periodically clean screens and replace inline filters to maintain stable measurements.
3.4 Electrical Connection
The WF282A supports I²C (up to 3.4 MHz) and SPI (up to 10 MHz); here we use I²C. Wire VCC→3.3 V, GND→GND, SDA→A4, and SCL→A5 on an Arduino or MCU, and place 4.7 kΩ pull‑up resistors on SDA and SCL lines to keep the bus idle high and prevent signal drift. Keep wiring short (≤ 100 mm) and bundle signal lines separately from high‑current cables to minimize EMI. After power‑on, scan for I²C address 0x76/0x77 to verify the sensor. In firmware, configure 16× oversampling and an IIR filter coefficient of 4 to balance resolution and response time.

4. Data Acquisition & Processing
4.1 Sampling Rate & Oversampling
We set the WF282A sampling interval to 500 MS (2 Hz), balancing the need to track dynamic pressure fluctuations from fan speed changes with ultra‑low power consumption (~2.7 μA). To improve resolution and reduce noise, we enabled 16× pressure oversampling and configured the on‑chip IIR filter with coefficient 4 (Filter_X4), maintaining a fast enough response for sub‑second measurement requirements.
4.2 Filtering Strategy
In addition to the WF282A’s internal IIR filter, we implemented a 10‑point moving‑average filter on the Arduino side, summing and averaging every 10 consecutive readings to remove short‑term spikes and RF interference. This dual‑stage filtering produces a smoother pressure signal while preserving significant events like fan start‑stop transients.
4.3 Baseline Calibration
To eliminate ambient barometric drift from relative static‑pressure measurements, we capture and average readings over the first 10 seconds after power‑up, using this as a zero‑baseline. Subsequent measurements subtract this baseline to output the net static‑pressure change. This auto‑calibration cancels out typical ±1 hPa atmospheric variations without user intervention.
4.4 Error Analysis
According to Bosch’s datasheet, the WF282A’s typical RMS noise is about 1.3 Pa; with 16× oversampling and IIR 4 filtering, noise falls to ≈0.8 Pa. Our combined moving‑average further reduces random fluctuations to within ±2 Pa under lab conditions.
5. Experimental Results & Analysis
5.1 Test Setup
We used a high‑speed blower generating ~5 m/s airflow at the duct inlet. The static‑port tubing (20 mm silicone) connected to the WF282A featured a fine mesh screen to block particulates. An Arduino streamed pressure readings to a PC for real‑time logging and visualization.
5.2 Data Presentation & Comparison
Under full‑flow conditions, net static pressure jumped from 0 Pa baseline to ~100 Pa within one sampling interval, then stabilized with ±3 Pa fluctuations. Upon blower shutdown, pressure returned to near 0 Pa within 5 seconds, clearly capturing fan start, steady‑state, and stop phases.
5.3 Accuracy Assessment
In 20 repeated tests under identical conditions, the mean measured pressure was 98.7 Pa with a standard deviation of 3.1 Pa, aligning with WF282A’s specified noise characteristics after filtering. A calibration curve yielded an R² ≥ 0.998, confirming excellent linearity and accuracy.
5.4 Improvement Recommendations
Future work could involve multi‑port differential measurement to cancel environmental disturbances, or integrate a combined temperature/humidity sensor (MISALNYA., WF282A) for multi‑parameter compensation, enhancing robustness in complex conditions.
Kesimpulan
This project employs a sidewall static port and short tubing to couple a WF282A sensor for precise static pressure sampling of a DC‑driven fan airflow. Leveraging the WF280A’s 0.01 hPa resolution and ±0.12 hPa accuracy, combined with 16× oversampling, on‑chip IIR filtering, and a 10‑point moving average, measurement precision was improved to within ±3 Pa. Experiments with ~5 m/s airflow showed net static pressure jumping from 0 Pa to ~100 Pa, stabilizing within ±3 Pa; twenty trials yielded an average of 98.7 Pa, a 3.1 Pa standard deviation, and a linear R² ≥ 0.998. The low‑cost, easy‑to‑install system, using I²C communication, supports multi‑port differential measurement and has excellent scalability and robustness. This approach offers a cost‑effective, reproducible solution for fan performance assessment and ventilation monitoring in both residential and industrial settings, enabling engineers and hobbyists to rapidly deploy airflow monitoring systems.
The above introduction only scratches the surface of the applications of pressure sensor technology. We will continue to explore the different types of sensor elements used in various products, how they work, and their advantages and disadvantages. If you’d like more detail on what’s discussed here, you can check out the related content later in this guide. If you are pressed for time, you can also click here to download the details of this guides air pressure sensor product PDF data.
For more information on other sensor technologies, please visit our sensors page.